For sidewalks and concrete heat island countermeasures!
"Highly reflective heat shielding paint R" is a high-reflectance heat-shielding paint that uses special pigments that efficiently reflect the near-infrared rays (heat rays) of sunlight.
Moreover, it is a water-based paint that is friendly to the global environment, and can be applied with a simple brush or roller coating method.
By coating pavement surfaces and rooftops (roofs), the temperature rise caused by the glaring sunlight can be mitigated, so it is a product that can alleviate the heat island phenomenon.
Main use
Asphalt, concrete, mortar surfaces
*Highly reflective heat-shielding paint "Highly reflective heat shielding paint S-II" to prevent temperature rise in metal boxes and to prevent heat dissipation from internal equipment
→Details of Highly reflective heat shielding paint S-II
Feature
- Easy-to-handle 1-liquid water-based paint
-
Can be used as is after opening the can.
No need to worry about solvent odor or ignition.
It does not disturb the asphalt surface.
Environmentally friendly water-based paint. - Excellent workability
-
It can be applied by brush or roller, and is easy to apply.
You can also spray paint. - Excellent durability
-
Since modified acrylic resin is used, it adheres well to both asphalt and mortar surfaces.
Excellent water resistance and weather resistance. - Hue can be selected from 13 colors
Properties and test results
Performance evaluation | 評価項目 | Performance value | remarks | |
---|---|---|---|---|
Properties | viscosity | 72KU | 23°C, Stomer viscosity system | |
density | 1.46g/ml | 23℃ | ||
Residue after heating | 65% | |||
Drying time | when dry | finger touch | 20 minutes |
23°C (10℃: 12 hours, 30℃: 2 hours) |
Curing | 3 hours | |||
Coating performance | adhesion | 100/100 | ||
Abrasion resistance | No aggregate | 120mg |
Tapered S-33 polishing paper According to JIS K 5665 |
|
with aggregate | 60mg | |||
Slip resistance value (Wet) | 50 | Non-slip surface, portable skid tester | ||
water resistant | Good | According to JIS K 5665 | ||
Alkali resistance | Good | According to JIS K 5665 | ||
Gasoline resistance | Good | 1 hour | ||
softening | 3 hours |
Heat shielding properties
solar reflectance
Product to be evaluated
|
solar reflectance
|
---|---|
Highly reflective heat shielding paint R
(Gray: equivalent to N-6) |
52.5%
|
* Measurement organization: Japan Paint Inspection Association
* Measurement conditions: Tokyo Metropolitan Government Bureau of Environment's standard for highly reflective paints
spectral reflectance
Surface temperature measurement data (by indoor irradiation test method)
Construction example
Example of NTT Laboratories parking lot
- A temperature reduction effect of 10°C or more can be observed when comparing the Highly reflective heat shielding paint R coated area with the uncoated asphalt surface.
- Even in comparison with the general paint of the same color as Highly reflective heat shielding paint R. The temperature has been reduced by about 7°C.
Example of the roof of the NTT laboratories chemical warehouse
- Comparing the Highly reflective heat shielding paint R painted part and the unpainted part, a maximum temperature reduction effect of about 12°C is recognized, and the overall temperature reduction is about 10°C.
- As a result of measuring the temperature directly under the ceiling of the painted and unpainted parts of the chemical cabinet, the temperature of the painted part on the left side and the temperature of the unpainted part on the right side were almost the same before painting. In fine weather, the room temperature of the painted part on the left is 2-3°C lower than that of the unpainted part.
Construction specifications
Asphalt, concrete, mortar surfaces
process
|
Material name
|
Application amount
(kg/ m2) |
paint interval
(20℃) |
---|---|---|---|
Primer (Note)
|
Highly reflective heat shielding paint water-based sealer
|
0.20
|
2 hours or more
|
1st layer
|
Highly reflective heat shielding paint R color sand |
0.30
0.12 |
1H or more
|
2nd layer
|
Highly reflective heat shielding paint R color sand |
0.30
0.12 |
ambulatory
3 hours or more |
(Note): For asphalt surfaces, the undercoating process can be omitted.
Commodity composition
Product name
|
hue
|
Packing
|
---|---|---|
Highly reflective heat shielding paint R
|
13 colors |
15kg/can
|
Highly reflective heat shielding paint water-based sealer
|
milky white
|
15kg/can
|
color sand | 6.7 white |
25kg
|
Safety, etc.
- Highly reflective heat shielding paint R and Highly reflective heat shielding paint /Aqueous Sealer are water-based paints. Never use thinners. (Except: cleaning of equipment, etc.)
- Dangerous goods classification: non-dangerous goods
- Avoid storage and transportation at temperatures below 0°C and above 50°C.
catalog download
Highly reflective (heat shielding) paint Highly reflective heat shielding paint series | 1.1MB | download |
---|
Request for materials / inquiries
Please feel free to contact us using the form for a purchase estimate and details.