Home > Equipment Maintenance > Humidity control sheet to prevent condensation > Humidity control sheet to prevent condensation

Humidity control sheet to prevent condensation

Ministry of Land, Infrastructure, Transport and Tourism New Technology Information System (NETIS) Registered Product NETIS Registration Number: KT-180094-VE
Contact us

Prevents condensation for a long period of time without using electric power, realizing maintenance-free equipment inspection

G-Breath is a product that has been NETIS VE rated for its effectiveness in social infrastructure and public construction.
A special humidity control sheet that "breathes" protects electrical equipment and equipment from malfunctions and other condensation problems.

Even though I have waterproof measures, the equipment breaks down ... The cause is dew! ??

images images
If the electrical equipment has a waterproof structure, it protects the electrical equipment from water and dust. However, in many cases, the high humidity and dew condensation that occur when the air inside the equipment cools cannot be prevented, resulting in failure. Equipment that plays a particularly important role, once a problem occurs, has a huge impact and damages credit, and daily maintenance and preventive maintenance cannot be neglected.

The image below is an example of condensation damage. Condensation is occurring inside the sealed power distribution board (left). As a result, corrosion occurs on the metal parts inside the switchboard (middle, right), which can lead to equipment failure, malfunction, and electrical leakage.

An example of condensation damage

 

Solved with condensation prevention sheet "Humidity Control Sheet"!

NTT-AT 's anti-condensation sheet "Humidity Control Sheet" is a special sheet *1 with excellent humidity control properties that prevents condensation and can be used for a long time, enabling smart maintenance that reduces maintenance costs. Furthermore, it is an ecological product that is friendly to the environment because it does not use electricity.

* 1: A product that has higher moisture absorption and desorption capacity than silica gel and has passed a long-term reliability test for introduction into communication equipment.
Image: G Breath
Various sizes of Humidity Control Sheet
Image: Image with M size G breath. It is 37 cm long with 3 stations.
A feeling of size of M size
Image: Specification example in an outdoor box
Solar power generation equipment M size installation example
Junction box: Dustproof / waterproof structure (IP55)

Case Study

Humidity control sheet to prevent condensation You can see an example of the application of the

Click here for application examples of Humidity Control Sheet

Three points to recommend "Humidity Control Sheet"

The amazing humidity control function shuts out condensation!

It absorbs moisture quickly when the humidity rises, just like breathing, and releases moisture quickly when the humidity drops, suppressing fluctuations in humidity and preventing condensation. The anti-condensation sheet "Humidity Control Sheet" is a product that complies with the RoHS Directive.

In our outdoor tests, the humidity inside the box without the anti-condensation sheet "Humidity Control Sheet" (blue) changes according to the outside air humidity (green), while the inside of the box with the anti-condensation sheet "Humidity Control Sheet" Humidity (red) always maintains a certain range of humidity.

Example of using Humidity Control Sheet
Humidity measurement test of anti-condensation sheet "Humidity Control Sheet"
【Measurement condition】
Test box volume: 13.9 liters (with a φ5 mm vent on the bottom)
Condensation prevention sheet "Humidity Control Sheet" (postcard size) installed on the lid
Measurement location: Outdoors in Tokyo
Measurement period: Excerpt from 2 weeks
Humidity measurement test of anti-condensation sheet "Humidity Control Sheet"

Long life & maintenance free

Humidity Control Sheet wicks away moisture without the need for high temperatures or sun drying to regenerate its wicking ability. Therefore, it responds to daily humidity fluctuations. Performance is maintained for a long period *2 by repeatedly performing moisture absorption and desorption. In addition, since it is an ecological product that does not require electricity and does not require maintenance after installation, it reduces management effort and costs.

* 2: A communication infrastructure company with a track record of maintaining performance for about 10 years.
(The usable period varies depending on the structure of the enclosure to be installed and the environmental conditions.)

Versatility regardless of construction location

The anti-condensation sheet "Humidity Control Sheet" does not require electricity and is thin and light, so it can be easily installed in small spaces or on curved surfaces. We offer 4 different sizes, from business card size to small and large, according to the volume of the box to be constructed.

Humidity Control Sheet image

Specification

Size lineup and construction examples

Humidity Control Sheet image: There are 4 sizes. The specifications are as follows.

Item Dimensions (mm) Mass (g) Applicable volume (L)/sheet *
Humidity Control Sheet L 560×230×3 130 400
Humidity Control Sheet M 370×150×3 50 150
Humidity Control Sheet postcard size 100×148×1 10 25
Humidity Control Sheet business card size 55×91×1 3 7

The applicable volume varies depending on the structure of the enclosure to be installed and the installation environment. If you would like to calculate the size and number of Humidity Control Sheet, please feel free to contact us from the "Inquiry Form" at the bottom of the page.

Example of Humidity Control Sheet installation on terminal board dedicated to communication

Cost comparison with other companies' products and implementation effects

Cost comparison in measures against dew condensation using other means

G breath is an introduction effect
 

Effects of introducing Humidity Control Sheet

We will introduce the effect of introducing Humidity Control Sheet with the change in the number of outdoor electrical equipment failures (an example).
 
Effects of introducing Humidity Control Sheet
* Effects will vary depending on the structure of the equipment to be installed and the environmental conditions.


[Precautions for use]
If there is a risk of water ingress in the box on which this product is installed, take preventive measures before using it.
The applicable volume is a guideline for use in a closed space. It depends on the environmental conditions.
This product does not guarantee the failure prevention of equipment.

Why does it condense?

 

We conducted an experiment to see how the presence or absence of the anti-condensation sheet "Humidity Control Sheet" affects changes in temperature and humidity.

 


 

Download materials

Condensation prevention sheet "Humidity Control Sheet" pamphlet 1.3 MB

Material "Why does dew condensation occur in a box with a waterproof structure? 』

Condensation was the cause of equipment failures, malfunctions, and electrical leaks! ?
This document explains why condensation occurs inside waterproof or sealed switchboards and electrical products, and what to do about it. (Japanese)

Document request

Condensation prevention sheet Humidity Control Sheet REACH, RoHS compliant product information

After submitting your application through the request form, an email containing "Information on Chemical Substances Contained in G-Breath Condensation Prevention Sheet" will be sent to the email address you registered.
You can download a PDF of the REACH, RoHS compliant product information for the G-Breath Condensation Prevention Sheet from the URL in the email.

Request for information on contained chemical substances

Inquiries

On the "Frequently Asked Questions" page, we introduce frequently asked questions about the anti-condensation sheet "Humidity Control Sheet".
Please read through and contact us.

Go to FAQ page

For customers who want to try Humidity Control Sheet and are considering introducing it

For information on how to select the size and number of Humidity Control Sheet, and how to install them, please feel free to contact us using the "Inquiry Form". Once again, we will contact you from our technical staff who have experience in troubleshooting infrastructure equipment equipment.
Contact us

Product Line

close up

Service list

close up

List of proposals for problem solving

close up

Catalog list

close up